Transformers

TA1626 Series
Minitype Precision AC Current Transformers

TA1626 Series Minitype Precision AC Current Transformers, Трансформаторы

1.Features:

  • Being able to be directly welded on PCB, beautiful outline;
  • Completely encapsulated, strong mechanical and environmental endurance, high voltage insulating ability, high accuracy, safe and reliable.

2.Conditions of usage:

  • Circumstance temperature: -55...+85°C;
  • Relative humid <90% при 40°C;
  • Atmospheric pressure: 860~1060mbar (650~800mmHg approximately);

3.Range of working Frequency: 20Hz~1kHz

4.Insulation Rating: Class F (155°C).

5.Safety features:

  • Insulation resistance: >1000MOm in normal condition;
  • Insulation withstand voltages: 6000V 50Hz/1min;
  • Fire proof: accord with the grade of UL94-Vo

6.Outline Drawing, Installation Dimention and Coil Diagram

TA1626 Series Minitype Precision AC Current Transformers, Трансформаторы

7.Typical Usage and Parameters:

The parameters in this application as shown in the right figure are listed in Table 1:

Table 1

Model Rated
Input
current
Rated
Output
current
Rated
sampling
resistance
Rated
sampling
voltage
Phase
Shift
Non
Linearity
Linear
Range
Withstand
Voltage
TA1626-1 50A 25mA 200 Om 5.0V <50` <0.5% >3 times
of rated value
>6kV
TA1626-1M 50A 25mA 140 Om 3.5V <19` <0.25% >2 times
of rated value
TA1626-2 50A 50mA 50 Om 2.5V <50` <0.5% >3 times
of rated value
TA1626-2M 50A 50mA 35 Om 1.75V <25` <0.25% >2 times
of rated value
TA1626-3 75A 50mA 100 Om 5.0V <60` <0.5%
TA1626-3M 75A 50mA 50 Om 2.5V <20` <0.25%
TA1626-4 75A 100mA 25 Om 2.5V <60` <0.5%
TA1626-4M 75A 100mA 12.5 Om 1.25V <25` <0.25%

Remarks:
a.In practical applications, the sampling resistor should be smaller than or equal to the rated value given in table above in order to improve the non-linearity and phase shift.
b.We can have it customer-made if required current ratio is not listed in the table above.

8.Attention:

  • The primary of the current transformer must be connected in series with the loop of the measured current. The secondary should operate in a mode of near short circuit.
  • The secondary of the current transformer is not allowed to be open circuit, Do Not install any fuse.

 

  • Цены, опубликованные в Магазине, могут не являться окончательными и предназначены только для предварительного ознакомления.
    Информацию о наличии товаров и свежих ценах уточняйте у менеджеров, они устанавливают окончательные цены при оформлении заказа в зависимости от количества товара и истории клиента. Или нажмите ссылку: sales@dart.ru
  • Представленная техническая информация и размеры на чертежах, опубликованных на сайте, носят справочный характер и не предназначены для использования в конструкторской документации без согласования с нами.
    Для получения актуализированной технической информации нажмите ссылку: alex@dart.ru
  • Возможность поставки товаров, где не указан код товара, уточняйте у наших менеджеров.
  • Перед закладкой компонентов в серийные изделия необходимо запрашивать образцы!
  ©1990-2024 Компания ДАРТ. Все права защищены.