Transformers

TA2030 Series
AC Current Transformers

TA2030 Series AC Current Transformers, Трансформаторы

1.Features:

  • Standard plug-in leads for output coil, easy to use with elegant outline.
  • Completely sealed, strong mechanical and environmental endurance, strong dielectric strength, safe and reliable.

2.Ambient conditions:

  • Ambient temperature: -55...+85°C;
  • Relative humidity <90% при 40°C;
  • Atmospheric pressure: 860~1060mbar (about 650~800mmHg);

3.Range of working Frequency: 20Hz~20kHz

4.Insulation Rating: Class F (155°C).

5.Safety features:

  • Insulation resistance: >1000MOm in normal condition;
  • Insulation withstand voltages: 6000V 50Hz/1min;
  • Fire retardancy: In conformity with UL94-Vo

6.Outline Drawing, Installation Dimention and Coil Diagram

TA2030 Series AC Current Transformers, Трансформаторы


7.Typical Usage and Parameters:

The parameters in this application as shown in the right figure are listed in table below.

Model Rated
Input
current
Rated
Output
current
Rated
sampling
resistance
Rated
sampling
voltage
Phase
Shift
Non
Linearity
Linear
Range
Withstand
Voltage
TA2030-00 120A 40mA 150 Om 6V <6` <0.2% >1.5 times
of rated
value
>6kV
TA2030-00M 120A 40mA 187.5 Om 7.5V <7.5` <0.25%
TA2030-01 100A 50mA 80 Om 4V <8` <0.2%
TA2030-01M 100A 50mA 100 Om 5V <10` <0.25%
TA2030-02 90A 60mA 50 Om 3V <10` <0.2%
TA2030-02M 90A 60mA 62.5 Om 3.75V <12.5` <0.25%
TA2030-03 60A 60mA 30 Om 1.8V <10` <0.2%
TA2030-03M 60A 60mA 37.5 Om 2.25V <12.5` <0.25%

Remarks:
a.In practical applications, the sampling resistor should be smaller than or equal to the rated value given in table above in order to improve the non-linearity and phase shift.
b.We can have it customer-made if required current ratio is not listed in the table above.

8.Attention:

  • The primary of the current transformer must be connected in series with the loop of the measured current. The secondary should operate in a mode of near short circuit.
  • The secondary of the current transformer is not allowed to be open circuit, Do Not install any fuse.

 

  • Цены, опубликованные в Магазине, могут не являться окончательными и предназначены только для предварительного ознакомления.
    Информацию о наличии товаров и свежих ценах уточняйте у менеджеров, они устанавливают окончательные цены при оформлении заказа в зависимости от количества товара и истории клиента. Или нажмите ссылку: sales@dart.ru
  • Представленная техническая информация и размеры на чертежах, опубликованных на сайте, носят справочный характер и не предназначены для использования в конструкторской документации без согласования с нами.
    Для получения актуализированной технической информации нажмите ссылку: alex@dart.ru
  • Возможность поставки товаров, где не указан код товара, уточняйте у наших менеджеров.
  • Перед закладкой компонентов в серийные изделия необходимо запрашивать образцы!
  ©1990-2024 Компания ДАРТ. Все права защищены.