Transformers

TA4052 Series
AC Current Transformers

TA4052 Series AC Current Transformers, Трансформаторы

1.Features:

  • Flexible in installation modes: fixable on primary wire or bottom board;
  • Suitable for multi-form of primary wires, such as flat-type wires, round wires or bottom cables;
  • Provided with four output terminals to realize variable ratios output;
  • Output terminals are standard plug pins, easy and solid to make connection;
  • Completely sealed, strong mechanical and environmental endurance, strong dielectric strength, elegant outline.

2.Ambient conditions:

  • Ambient temperature: -55...+85°C;
  • Relative humidity <90% при 40°C;
  • Atmospheric pressure: 860~1060mbar (about 650~800mmHg);

3.Range of working Frequency: 20Hz~1kHz

4.Insulation Rating: Class F (155°C).

5.Safety features:

  • Insulation resistance: >1000MOm in normal condition;
  • Insulation withstand voltages: 6000V 50Hz/1min;
  • Fire retardancy: In conformity with UL94-Vo

6.Outline Drawing, Installation Dimention and Coil Diagram

TA4052 Series AC Current Transformers, Трансформаторы

Remark: Terminals 1, 4 are reserved for other variable ratios. Don’t lead out unless needed.

Installation instruction

Mounted on bottom board:
Take two support legs (included in package along with the product) and insert them into the sockets as shown in Fig. below. The center distance between the mounting holes is 42.5x40; The diameter of the mounting hole for the support leg is Ø 5.0, and then use M4 screw to fix the current transformer on the bottom board.

Mounted on primary wire:
Take one support leg with M5 hole (included in package along with the product) and insert it into the socket as shown in Fig. below. The center distance between the M5 hole is 42.5; fix the current transformer on the primary wire with M4 screw.


7.Typical Usage and Parameters:

The parameters in this application as shown in the right figure are listed in table below.

Model Rated
Input
current
Rated
Output
current
Rated
sampling
resistance
Rated
sampling
voltage
Phase
Shift
Non
Linearity
Linear
Range
Withstand
Voltage
TA4052-1 400A 0.1A 75 Om 7.5V <30` <0.5% 4 times
of rated
value
>6kV
TA4052-2 400A 0.2A 25 Om 5V <30`

Remarks:
a.In practical applications, the sampling resistor should be smaller than or equal to the rated value given in table above in order to improve the non-linearity and phase shift.
b.We can have it customer-made if required current ratio is not listed in the table above.

8.Attention:

  • The primary of the current transformer must be connected in series with the loop of the measured current. The secondary should operate in a mode of near short circuit.
  • The secondary of the current transformer is not allowed to be open circuit, Do Not install any fuse.

 

  • Цены, опубликованные в Магазине, могут не являться окончательными и предназначены только для предварительного ознакомления.
    Информацию о наличии товаров и свежих ценах уточняйте у менеджеров, они устанавливают окончательные цены при оформлении заказа в зависимости от количества товара и истории клиента. Или нажмите ссылку: sales@dart.ru
  • Представленная техническая информация и размеры на чертежах, опубликованных на сайте, носят справочный характер и не предназначены для использования в конструкторской документации без согласования с нами.
    Для получения актуализированной технической информации нажмите ссылку: alex@dart.ru
  • Возможность поставки товаров, где не указан код товара, уточняйте у наших менеджеров.
  • Перед закладкой компонентов в серийные изделия необходимо запрашивать образцы!
  ©1990-2024 Компания ДАРТ. Все права защищены.