Transformers |
“Blue Fairy” T12 Model PCB Soldering Power Transformers
|
1.Features:
- Fully-encapsulated printed circuit board being able to be directly welded
and assembled, easy to use, perfect outline;
- Compact in structure, solid, vibration-proof, moisture-proof, flame-resistant,
and high dielectric strength;
- Higher power density with smaller size;
- Economical transformers in application, competitive price
2.Ambient Conditions:
- Ambient temperature: -10...+40°C;
- Relative humid <90% при 40°C;
- Atmospheric pressure: 860~1060mbar (650~800mmHg approximately);
3.Insulation Rating: Class B (130°C).
4.Safety features:
- Dielectric resistance: >1000MОм in normal condition;
- Insulation withstand voltages: Better than GB/T15290 standard requirements.
- Fire retardancy: In conformity with UL94-Vo;
- Insulation impact strength: Continuously 10 times impact of 6KV (50HZ)/50μS;
5. Rated Power: 12VA
6. Rated Voltage:
1) Standard series:
Primary: 220V±10% 50Hz/60Hz
Secondary:
single output:6V, 7.5V, 9V, 12V, 15V, 18V, 21V, 24V, 27V;
double output:2x6V, 2x7.5V, 2x9V, 2x12V, 2x15V, 2x18V, 2x21V, 2x24V, 2x27V
2) Non-standard series: It can be customized based on customer's requirements.
7. Universal Technical Parameters of T12 Series Standard Product:
No. |
Model |
Power |
Idle
Current |
Idle
Loss |
Voltage
Regulation
Ratio |
Temperature
Rise |
Weight
(g) |
Dimension
LxWxH
(mm3) |
18 |
T12 |
12VA |
<28mA |
<1.0W |
<15% |
<24°C |
300 |
51x43x36 |
8.Outline, Installation Dimension and Detailed Technical Parameters of T12
Primary pins |
Primary voltage |
Frequency |
Primary current |
Rating |
Max. |
Idle |
Full load |
1-6 |
220V |
242V |
50Hz /60Hz |
<28mA |
<73mA |
Model |
Windings |
Secondary voltage |
Secondary
current
(mA) |
Secondary
Pins |
Equivalent
internal
resistance
(Ом) |
Idle |
Full load |
T12-01 |
|
7.2V |
6V |
2000 |
8-11 |
0.8 |
T12-01B |
9V |
7.5V |
1600 |
1.2 |
T12-02 |
10.8V |
9V |
1333 |
1.7 |
T12-03 |
14.4V |
12V |
1000 |
3 |
T12-04 |
18V |
15V |
800 |
4.7 |
T12-05 |
21.6V |
18V |
667 |
6.8 |
T12-05B |
25.3V |
21V |
571 |
9 |
T12-06 |
28.9V |
24V |
500 |
12 |
T12-06B |
32.5V |
27V |
444 |
15.4 |
T12-07 |
|
2x7.2V |
2x6V |
2x1000 |
7-8
11-12 |
2x1.5 |
T12-07B |
2x9V |
2x7.5V |
2x800 |
2x2.4 |
T12-08 |
2x10.8V |
2x9V |
2x667 |
2x3.4 |
T12-09 |
2x14.4V |
2x12V |
2x500 |
2x6 |
T12-10 |
2x18V |
2x15V |
2x400 |
2x9.5 |
T12-11 |
2x21.6V |
2x18V |
2x333 |
2x14 |
T12-11B |
2x25.3V |
2x21V |
2x286 |
2x18.5 |
T12-12 |
2x28.9V |
2x24V |
2x250 |
2x24 |
T12-12B |
2x32.5V |
2x27V |
2x222 |
2x31 |
|
|
|
|
|
- Цены, опубликованные в Магазине, могут не являться окончательными и предназначены только для предварительного ознакомления.
Информацию о наличии товаров и свежих ценах уточняйте у менеджеров, они устанавливают окончательные цены при оформлении заказа в зависимости от количества товара и истории клиента. Или нажмите ссылку:
sales@dart.ru
- Представленная техническая информация и размеры на чертежах, опубликованных на сайте, носят справочный характер и не предназначены для использования в конструкторской документации без согласования с нами.
Для получения актуализированной технической информации нажмите ссылку:
alex@dart.ru
- Возможность поставки товаров, где не указан код товара, уточняйте у наших менеджеров.
- Перед закладкой компонентов в серийные изделия необходимо запрашивать образцы!
|
|
|
|
|